Back to top
60KVA Three Phase Online UPS
60KVA Three Phase Online UPS

60KVA Three Phase Online UPS

Price 525000 INR/ Unit

MOQ : 1 Unit

60KVA Three Phase Online UPS Specification

  • Cooling System
  • Forced Air Cooling
  • Port Type
  • Input/Output Terminal Block
  • Batteries Type
  • SMF VRLA
  • Material
  • Sheet Metal
  • Efficiency (%)
  • 95%
  • Power Capacity
  • 60KVA
  • Battery Backup
  • Long backup
  • Control System
  • Microprocessor Controlled
  • Type
  • Standby
  • Phase
  • Three Phase
  • Protection
  • Over Voltage
  • Output Voltage
  • 415V AC
  • Recharge Time
  • 8 hours
  • Back-Up Time
  • 60 minutes
  • Interface Type
  • LCD Display
  • Size
  • 1400mm x 850mm x 1700mm
  • Weight
  • 650 kg
  • Color
  • Black & Grey
  • Display Type
  • Digital/LCD monitoring panel
  • THD (Total Harmonic Distortion)
  • <3%
  • Transfer Time
  • Zero (True Online)
  • Input Voltage Range
  • 340V - 475V AC
  • Noise Level
  • <55 dB at 1 Meter
  • Bypass
  • Automatic & Manual bypass available
  • Operating Temperature
  • 0°C to 45°C
  • Crest Factor
  • 3:1
  • Frequency Range
  • 50Hz ± 5%
  • Installation Type
  • Floor Mounted
  • Humidity
  • 0% - 95% Non-Condensing
  • Alarms
  • Low Battery, Overload, System Fault
  • Monitoring
  • Remote monitoring supported
  • Battery Quantity
  • 40 x 12V
  • Communication Interface
  • RS232/USB/ SNMP (optional)
 

60KVA Three Phase Online UPS Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About 60KVA Three Phase Online UPS

The 60KVA Three Phase Online UPS offers a reliable, scalable and user-friendly solution to ensure availability of various critical applications. It offers protection and provides lower cost of ownership through its digital architecture and range of options which can be customized specifically as per needs. 

Features

  • Fully digital, twin DSP controlled
  • Rated at 0.9 output power factor to deliver more active power
  • Handle leading power factor loads without KW de-rating under specified conditions
  • On-line double conversion IGBT based PWM Inverter
  • Wide input voltage tolerance (+20/-20%)
  • Wide input frequency range of 45Hz to 65Hz
  • High overload capability of static bypass 
  • Built-in maintenance by pass front access for spares replacement and preventive maintenance
  • Easy dual bus configuration architecture

Built investment protection:

  • Automatic battery testing
  • Field stability of EOD of the battery
  • Selectable times for boost charging duration of the battery
  • Protection against deep discharge of battery
  • Battery circuit breaker instead of using AC isolator
  • Short-circuit proof inverter
  • Back-feed protection
  • D-level lightning protection
  • With 3 auxiliary power supply to ensure redundancy under any condition
  • Standard dry contacts
  • Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range
  • Choice of array of input harmonic filter options
  • Using in industry for laser cutting machine, IT Load, hospital load, mixed load

Configuration

3 Phase IN - 3 Phase OUT

Usage/Application

Laser cutting machine, MRI Machine, Hospital, big data center, IT, Medical instrument, PLC, CNC, CMS

Short Circuit

Yes

Thd - Linear Load

3%

Frequency Range

50 Hz (45HZ TO 65HZ)

Dc Voltage

408 VDC

Voltage Tolerances

At Output +/- 1%

Safety Standard

IEC 62040 -1-1

Performance Standard

Design & Method - IEC 62040-3

Parallel Configuration

Yes

Overload

101-110% 60 mins,111-125% -10 mins,125-150% - 1 mins

Output Waveform

Pure sine wave

Operating Temp Deg Celsius

0-40 Deg. C at Rated capacity 40-50 Deg. C UPS capacity linearly de-rated

Emc Standard

IEC 62040-2

Crest Factor

3:1

Output Voltage

380/400/415 VAC 3-W Plus Ground

Transfer Time

0 ms

Country of Origin

Made in India

Supported Battery Types

SMF

Recharge Time

10-12 hrs to 90% of battery AH Capacity

Number Of Batteries Supported

34 Nos

Charging Current

30 Amp

Battery Rating

External 12 V 150 AH * 2 Bank * 34 Nos

Battery Backup

2 Hrs

Brand

Emerson Vertiv

Topology

Double conversion Online UPS

Noise Level

<65 dBA

Waveform

Pure sine wave

Transient Recovery

20 ms to 1%

Storage Temperature

0-55 Deg.C

Weight

670 Kg

Efficiency

93%

Display Type

LCD Display and mimic panel

Dimension

D 810 x W 715 x H 1615 ( in mm)

Input Voltage

380/400/415 VAC 3-W Plus Ground

Audible Noise

55 dbA

Model Name/Number

LIEBERT HIPULSE-U

Capacity

60 KVA

Power Cord Length

Power cord not Provided. Terminal block provided

Form Factor

Tower Model

I Deal In

New Only

Back Up Time

2 HRS

 



Comprehensive Power Protection

Designed for enterprise and industrial environments, the 60KVA Three Phase Online UPS offers seamless power delivery during disruptions. With true online double conversion and zero transfer time, your vital systems remain protected from voltage fluctuations, noise, and outages. The integrated sheet metal construction and microprocessor-based controls deliver consistent performance and reliability in mission-critical operations.


Advanced Monitoring & Remote Access

Equipped with a digital LCD panel, this UPS provides instant status and fault notifications. Remote management is enabled through RS232, USB, or optional SNMP interfaces, facilitating oversight from virtually any location. Audible and visual alarms allow prompt identification of battery, overload, or system fault conditions, while comprehensive monitoring tools make preventive action simple.


Extended Runtime and Rapid Recovery

With 40 x 12V SMF VRLA batteries and a 60-minute backup time, this UPS ensures your operations continue smoothly during prolonged power interruptions. The battery system recharges fully within 8 hours, supporting rapid deployment for uninterrupted service. Forced air cooling and efficient design also contribute to a long service life and optimal performance.

FAQ's of 60KVA Three Phase Online UPS:


Q: How does the 60KVA Three Phase Online UPS ensure continuous power supply during an outage?

A: This UPS utilizes a true online double-conversion design, which continuously powers your equipment via the inverter, ensuring zero transfer time between mains and battery-so your critical systems experience no interruption when a power outage occurs.

Q: What is the installation process for this UPS system in a commercial setting?

A: The unit is designed for floor-mounted installation and connects to your facility's three-phase input and output via terminal blocks. Professional installation by a certified technician is recommended to ensure safe integration and system commissioning.

Q: When should I perform routine maintenance on the UPS and batteries?

A: It's advisable to conduct routine maintenance every 6 to 12 months. This includes inspecting battery integrity, testing alarms, cleaning the cooling system, and reviewing the communication interfaces for optimal remote monitoring and control.

Q: Where can I access system monitoring and manage UPS alerts remotely?

A: You can monitor and manage the UPS remotely using the RS232, USB, or optional SNMP communication interfaces. System status, alarms, and operational data can be accessed through compatible monitoring software, enabling proactive management from onsite or remote locations.

Q: What benefits does the microprocessor-controlled system provide?

A: The microprocessor-controlled system enhances reliability by enabling precise management of power conversion, rapid fault detection, and optimized charging cycles for the SMF VRLA batteries. This results in higher efficiency, superior protection, and reduced risk of operational issues.

Q: How does the UPS protect connected equipment from electrical disturbances?

A: With output THD under 3% and a crest factor of 3:1, the UPS provides clean and stable power. It includes protections against over-voltage, overload, low battery, and system faults, alongside both automatic and manual bypass options for safe equipment maintenance and disaster recovery.

Q: What is the typical backup time and recharge duration for this UPS model?

A: The system offers a backup duration of up to 60 minutes at full load with its 40 x 12V SMF VRLA batteries. After a power outage, it requires approximately 8 hours for the batteries to fully recharge to optimal capacity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Three Phase Online UPS Category

High Frequency Ups

High Frequency Ups

Price 265000 INR / Piece

Minimum Order Quantity : 1 Piece

Phase : Single Phase

Type : OnLine

Warranty : 1 Year

Color : Black

Three Phase Online UPS

Three Phase Online UPS

Price 145000 INR / Piece

Minimum Order Quantity : 1 Piece

Phase : Three Phase

Type : OnLine

Warranty : 1 Year

Color : Black

Emerson Liebert Hipulse-U 60KVA Three Phase Online UPS

Emerson Liebert Hipulse-U 60KVA Three Phase Online UPS

Price 561500 INR / Piece

Minimum Order Quantity : 1 Piece

Phase : Three Phase

Type : OnLine

Warranty : 2 Years

Color : Black

Emerson Liebert Hipulse-U 120KVA Three Phase Online UPS

Emerson Liebert Hipulse-U 120KVA Three Phase Online UPS

Price 1090000 INR / Piece

Minimum Order Quantity : 1 Piece

Phase : Single Phase

Type : OnLine

Warranty : 2 Years

Color : Black